all columns are in the correct position before operation
the capacity of the load is sufficient
the batteries are supplied with power
the mode selection switches are in the correct position
Before daily use
Make sure that
all wheel grippers are in the correct position before operation
the capacity of the payload is sufficient
the batteries are powered
the mode selection switches are in the correct position
2.10

Final work

Before commissioning, check all fastening screws, electrical, pneumatic and hydraulic lines
and tighten them if necessary.
Caution: Some of these must be checked at regular intervals and tightened if necessary.
2.11

Oil filling and venting

Do not operate the pump-motor unit without oil.
This may damage the pump.
Oil filling and bleeding
1. Remove the oil filler plug and fill approx. 5 liters of the recommended hydraulic fluid into the tank.
2. Set the power switch to 1 to switch on the wheel gripper
3. Set the mode selector switch to 1 to set the wheel lift to single mode.
4. Raise the fork to maximum height and add more hydraulic fluid until the tank is full.
5. Lower the fork completely
6. Open the bleed screw of the cylinder by turning it counterclockwise.
7. Close the bleed screw again when fluid flows out
8. Repeat this procedure to completely bleed the hydraulic system of the other wheel grippers