IBM System x3755 Problem Determination And Service Manual page 167

Hide thumbs Also See for System x3755:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, System x3755 Type 8877 and 7163," on page 25 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
System-error log message
Slot n error (possible timeout condition)
Remote Login Successful. Login ID:
Secondary HT2100 initiated sync flood: PCI-e
slot n error
Single fan failure
Action
1. Reseat the failing adapter.
2. Replace the failing adapter.
3. (Trained service technician only) Replace the I/O board, see
"Removing the I/O board assembly" on page 68 and "Replacing
the I/O board assembly" on page 69.
Information only
1. Reseat the failing adapter.
2. Replace the failing adapter.
3. (Trained service technician only) Replace the I/O board, see
"Removing the I/O board assembly" on page 68 and "Replacing
the I/O board assembly" on page 69.
Replace any missing or failed fans or power supplies.
151
Chapter 5. Diagnostics