v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, System x3755 Type 8877 and 7163," on page 25 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
BMC log message
Fan 4 detected
Assertion 00 (Not
detected)
Fan 4 detected
Assertion 01 (Presence
detected)
Fan 5 detected
Assertion 00 (Not
detected)
Fan 5 detected
Assertion 01 (Presence
detected)
Fan 6 detected
Assertion 00 (Not
detected)
Fan 6 detected
Assertion 01 (Presence
detected)
Drive 1 status
Drive 2 status
Drive 3 status
Drive 4 status
Power supply 1 status
Assertion 00 (Presence
detected)
Power supply 1 status
Assertion 01 (Power
supply failure) or 03
(Power supply ac loss)
Power supply 2 status
Assertion 00 (Presence
detected)
Sensor
Sensor
number
type
Action
53
04
Replace or install the fan.
53
04
Information only
54
04
Replace or install the fan.
54
04
Information only
55
04
Replace or install the fan.
55
04
Information only
60
C1
Information only
61
C1
Information only
62
C1
Information only
63
C1
Information only
70
08
Information only
70
08
1. Check the primary voltages to the power supply.
2. Reseat power supply 1.
3. Replace power supply 1.
4. (Trained service technician only) Replace the I/O board, see
71
08
Information only
"Removing the I/O board assembly" on page 68 and
"Replacing the I/O board assembly" on page 69.