Riello START KIS Series Installer And User Manual page 5

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 3
PARAMETERS
Lower Wobbe index (at 15°C-1013 mbar)
Net Calorific Value
Supply nominal pressure
Minimum supply pressure
Burner: diameter/length
Diaphragm: holes number - holes diameter
CH maximum gas capacity
DHW maximum gas capacity
CH minimum gas capacity
DHW minimum gas capacity
Number of fan rotations with slow ignition
Maximum number of CH fan rotations
Maximum number of DHW fan rotations
Minimum number of CH/DHW fan rotations
Max n° of DHW fan rotations in C(10) configuration (Ø80/125 ● Ø80-80)
Min n° of CH/DHW fan rotations in C(10) configuration (Ø80/125 ● Ø80-80)
2.1
Erp data
Parameter
Seasonal space heating energy efficiency class
Water heating energy efficiency class
Rated heat output
Seasonal space heating energy efficiency
Useful heat output
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature regime (**)
Useful efficiency
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In Stand-by mode
Other parameters
Stand-by heat loss
Pilot flame energy consumption
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxides
For combination heaters
Declared load profile
Water heating energy efficiency
Daily electricity consumption
Daily fuel consumption
Annual electricity consumption
Annual fuel consumption
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
NOTE: with reference to the Delegated Regulation (EU) No. 811/2013, the information in the table can be used for completing the product data sheet and
the labelling for room heating appliances, for mixed heating appliances, for all those appliances for enclosed space heating, for temperature control devices
and solar devices:
DEVICES
OUTDOOR TEMPERATURE SENSOR
OT+ CONTROL PANEL
OUTDOOR TEMPERATURE SENSOR + OT+ CONTROL PANEL
UM
METHAN GAS (G20)
MJ/m³S
45,67
MJ/m³S
34,02
mbar (mm H2O)
20 (203,9)
mbar (mm H2O)
10 (102,0)
25 KIS
mm
70/88
n° - mm
1 - 4,5
Sm³/h
2,12
kg/h
-
Sm³/h
2,64
kg/h
-
Sm³/h
0,33
kg/h
-
Sm³/h
0,33
kg/h
-
5.500
rpm
rpm
7.000
8.700
rpm
1.500
rpm
9.200
rpm
2.100
rpm
Symbol
-
-
Pnominal
ηs
P4
P1
η4
η1
elmax
elmin
PSB
Pstby
Pign
QHE
LWA
NOx
ηwh
Qelec
Qfuel
AEC
AFC
CLASS
II
V
VI
5
LPG (G31)
70,69
88
37 (377,3)
-
30 KIS
25 KIS
30 KIS
70/105
70/88
70/105
1 - 5,1
1 - 3,6
1 - 3,8
2,64
-
-
1,55
1,94
3,17
-
-
1,94
2,33
0,42
-
-
0,39
0,39
0,42
-
-
0,39
0,39
5.500
5.500
5.500
6.900
6.900
6.800
8.300
8.500
7.900
1.500
2.050
1.700
7.000
-
2.100
-
25 KIS
30 KIS
Unit
A
A
A
A
19
24
kW
93
93
19,4
24,4
kW
6,5
8,2
kW
87,3
87,6
98,5
98,2
32,0
38,0
12,0
12,0
3,0
3,0
30,0
32,0
-
-
42
56
50
53
22
22
mg/kWh
XL
XL
84
84
0,133
0,152
kWh
23,183
23,306
kWh
29
33
kWh
18
18
BONUS
2%
3%
4%
EN
-
-
-
-
-
-
-
-
%
%
%
W
W
W
W
W
GJ
dB
%
GJ

Advertisement

Table of Contents
loading