How To Extend The Control Unit Cable (Option) - Furuno FAR-3210 Installation Manual

Chart radar
Hide thumbs Also See for FAR-3210:
Table of Contents

Advertisement

2. WIRING
2.14

How to Extend the Control Unit Cable (option)

To extend the length of the cable between the control unit and the processor unit, use
the appropriate cable assembly for the control unit, as listed below.
• RCU-025: TET-16-045A (5/10/20/30 m)
• RCU-026: 6TPSH-XH12X2-LxxSP2 (5/10/20/30 m)
Note: When the control unit cable is 10 m or longer, the USB cable (TS-20-071-1, 5
m) that is supplied with the control unit cannot be used. Even if the USB cable is not
used, you can operate the control unit properly, but the USB port on the control unit is
deactivated.
2.14.1
Radar control unit (RCU-025)
Wiring for the control unit
1. Unfasten 12 binding screws (M3x8) from the bottom of the control unit to remove
the cover.
Note: Do not add stress to the cables connected to the control unit board when
removing the cover. When the serial number of the control unit is "200001" or later,
disconnect the cable from the J3 (see the figure on step 3) before removing the
cover.
2. Unfasten two screws to remove the cable clamp.
3. Release the control unit cable from the wiring clamp, then disconnect the cable
from the J1.
Unfasten two pan
head screws (M3×12)
to remove the cable
clamp.
Control unit cable
Serial number is "199999" or earlier
2-74
Binding screw
Serial number is "199999" or earlier
J1
Wiring clamp
Cable clamp
Binding screw
Serial number is "200001" or later
Wiring clamp
J1
Grommet
Grommet
Serial number is "200001" or later
J3
Unfasten two binding
screws (M3×8) to
remove the cable
clamp.
Control unit cable
Disconnect the cable
from J3 before
removing the cover.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents