Mounting the Polarizer Unit

What has to be
The filter unit has to be mounted on the horizontal shift plate with insertion of two
done
springs. This allows a tilting adjustment of the filter unit.
Necessary Tools
A flatblade screwdriver for M5 (No 7)
Mounting the
To mount the filter unit, follow the next procedure:
filter unit
Illustrations
D
C
E
Image 3
BARCO ——————————————————— 11
Step
Action
1
Remove the plastic protective foil from polarizer.
2
Place the filter unit (A) on the bottom side of the horizontal
shift plate (B) with insertion of 2 springs (C) on the place of
the fixation holes.
3
Fix the polarizer unit to shift plate using 2x screw with
washer (D) in such a way that the space between both
units is about 20mm.
4
Lock the screw end with a nut (E) to determine the adjust-
ment range and also to prevent drop of the polarizer when
adjusting too far.
B
A
Image 1
D
20m m
E