Connecting Plate For Fixed Pump (C2 And C4) - Bosch Rexroth SB11 Instruction Manual

Load-sensing control block for mobile applications
Hide thumbs Also See for Rexroth SB11:
Table of Contents

Advertisement

22/60
Load-sensing control block SB11 | About these products
Application
Internal function
Operation / control
Bosch Rexroth AG, RE 66177-B/2022-05-03
5�3�6 Connecting plate for fixed pump (C2 and C4)
Table 7: Internal functions
Position
Designation
Pressure compensator
LS pressure relief valve
Primary pressure relief valve
Shuttle valve
AP C2/C4 is used for an SB11 block for the open circuit (fixed pump).
The inlet and return lines of the flow are directed via AP C2/C4. AP C4 is identical
with AP C2, but with an additional N port for the pressure transmission.
Pressure compensator
according to the block-internal LS signal.
LS pressure relief valve
indirectly also the pressure in the block-internal P line by means of the pressure
compensator.
Primary pressure relief valve
indirectly also the pressure in the block-internal P line.
NOTICE! The primary pressure relief valve with its short response time and low
flow is applied for limitation of the pressure peaks in the supplied flow.
LS signal input
: For linking an external LS signal via a shuttle valve to the
internal LS chain.
AP C2/C4 does not have a manual operating element or external control.
Unloading of the secondary pressure relief valve in the EHR11-EHS via AP C2/
C4 is not possible for design reasons (return flow RfB).
: Controls the inlet flow to the connected SB11 valves
: Limits the pressure at the inlet port
: Limits the pressure at the inlet port
Information
optional
optional
optional
and
and

Advertisement