Technical specifications
10.1 SITRANS FUS060
Table 10-6
Display and controls
Display and controls
Display
Multi-display: 2 freely-selectable values
Are displayed simultaneously in two
lines
Operation
Table 10-7
Power supply
Power supply
Supply voltage
Standard version
Ex version
Power failure
Power consumption
Table 10-8
Cable options
Cable options
M20 cable gland set for FUS060 (M20) power and output connection, gray PA plastic, 2 pcs.
Order number
Cable cross section
Ambient temperature
Nominal torque
FUS060 ATEX version power and output connection, PA and brass, 1 x in blue (ATEX Ex i) and 1 x gray (ATEX Ex-e)
Order number
Cable cross section
Ambient temperature
Nominal torque Brass
Nominal torque PA
1/2" NPT cable gland set for FUS060 (NPT) power and output connection, gray PA plastic, 2 pcs.
Order number
Cable cross section
Ambient temperature
Nominal torque
M25 cable gland set for the FUS060 PA (M25) power and output connection, gray PA plastic, 2 pcs.
Order number
Cable cross section
Ambient temperature
Nominal torque
78
LCD, two lines with 16 characters each (backlight)
Volume flow, mass flow, volume, mass, flow velocity, sound velocity, ultrasonic sig‐
nal information, current, frequency, alarm information
4 infrared keys, hierarchical menu shown with codes
120 to 230 V AC ± 15% (50/60 Hz) or 19 to 30 V DC/ 21 to 26 V AC
19 to 30 V DC/ 21 to 26 V AC
No effect for at least 1 period (> 20 ms)
Approx. 10 VA / 10 W
C75196-Z1147-A18
6 ... 12 mm (0.24" ... 0.47")
-40 ... +100 °C (-40 ... +212 °F)
4.5 Nm
C75196-Z1147-A5
A5E49854397
5 ... 9 mm (0.20" ... 0.35")
-20 ... +95 °C (-4 ... +203 °F)
8 Nm
4.5 Nm
C75196-Z1147-A16
6 ... 12 mm (0.24" ... 0.47")
-40 ... +100 °C (-40 ... +212 °F)
4.5 Nm
085U3332
9 ... 16 mm (0.35" ... 0.63")
-40 ... +100 °C (-40 ... +212 °F)
4 Nm