Siemens SITRANS FUS060 Operating Instructions Manual page 118

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS FUS060:
Table of Contents

Advertisement

HMI menu structure
C.1 Menu items (FW Rev. 4.00.00-15)
Menu
Device function,
code
Parameters
7.1.4.2.
Displacement 2
3
7.1.4.2.
Trig. con 2 Up
4
7.1.4.2.
Trig. con 2 Dw
5
7.1.4.2.
AUTO cal. 2
6
7.1.4.2.
WET cal. 2
6
7.1.4.2.
WET Flow 2
7
7.1.4.3
Track 3
7.1.4.3.
Length 3
1
7.1.4.3.
Angle 3
2
118
Description
Displacement of path 2 (m)
Note: The value must be smaller than
the half entered pipe diameter (see
menu 7.1.3.2.2).
For 1-path the value must be set to 0
The signal trigger constant of the sec‐
ond path up.
The signal trigger constant of the sec‐
ond path down.
The AUTO calibration factor is auto‐
matically calculated
Note: Only shown if AUTO is selected
in menu 7.1.1
The WET calibration factor of the
path.
Note: Only shown if WET is selected
in menu 7.1.1
This value represents the calculated
flow
Note: Only shown if WET is selected
in menu 7.1.1
Length of path 3 (m). The distance
between the two ultrasonic transduc‐
ers of path 3, see Sensor parameters
(menu 7) (Page 61).
Angle of path 3
Factory setting
Setting options
Depending of sensor
0 to 1.5 m
size selected at order‐
ing
SONO 3100 and SO‐
-1.40 to +1.40
NOKIT:
-0.75
SONO 3100 (special
applications):
Depending on the or‐
dered system
SONO 3300:
Depending on the or‐
dered sensor
SONO 3100 and SO‐
-1.40 to +1.40
NOKIT:
-0.75
SONO 3100 (special
applications):
Depending on the or‐
dered system
SONO 3300:
Depending on the or‐
dered sensor
Depending on facto‐
0.0000010 to
ry calibration of the
100.0000000
transmitter, which is
(value with 7 frac‐
typically done to‐
tional digits)
gether with the or‐
dered sensor
Depending on facto‐
ry calibration togeth‐
er with ordered sen‐
sor
Depending of sensor
>0 to 8.0 m
size selected at order‐
ing
Depending of sensor
0 to 89°
size selected at order‐
ing
Operating Instructions, 09/2021, A5E01204521-AL
Read /
Write
Write
Write
Write
Read
Write
Read
Write
Write
SITRANS FUS060 with HART

Advertisement

Table of Contents
loading

Table of Contents