Ground Stack Array
Key hardware components must be inspected
before each use.
Any rigging components found to be defective,
or even suspect might be defective should be
replaced with equivalent approved part.
Always use properly rated installation hardware.
K-array is not responsible for any installing
equipment
and
manufactured by K-array.
Check building codes for weight distribution
requirements. Ensure that the total weight of the
loudspeakers and additional hardware assembly
in use is lower than the Working Load Limit (WLL).
Ground stacking the loudspeaker systems shall be
accomplished by knowledgeable and experienced
professionals.
Install the loudspeaker stack on a plain horizontal
surface.
Ensure that the location for the loudspeakers
stack and its support system provides for the
minimum clearances required for safety.
It is the user's responsibility to secure the
loudspeakers stack and its support system to
ground in order to avoid any damage or failure due
to any unintended hits, gust of wind, vibrations or
such.
accessories
that
are
Needed Equipment
Name
Description
Stacking hardware for
K-HCBASE2
Stacking hardware for
K-HCBASE
KH3 I and KH5 I
not
Rigging Procedure: Ground Stacked Line Array
1. Set the K-HCBASE or K-HCBASE2 stacking hardware on the
position.
2. Attach the bottom Mugello-KH unit to the base using four
quick-release pins.
3. Proceed stacking further line array elements on top.
4. Set the unit tilting angles.
Mugello-KH I
Image
KH2 I
User Guide
Apply to
KH2 I/KH2P I
KH3 I/KH3P I
KH5 I/KH5P I
21