230 V Ac, 3-Phase Wye System - K-array Mugello-KH I User Manual

Line array elements with electronic beam steering
Table of Contents

Advertisement

Mugello-KH I
User Guide
KH2 I
600 W @ 8 Ω load,
Power
Pink noise,
consumption
1/4 rated power
Use power cable with powerCon TRUE connector for powering
the Mugello-KH active array units:
1. insert the powerCon TRUE flying plug into the unit inlet;
2. rotate the powerCon TRUE plug clockwise. Once properly
plugged and powered, the system status LED lights on.
1
powerCON TRUE plug
The power joint cable with powerCON TRUE plugs provided
can be used to daisy chain multiple Mugello-KH active array
elements. Refer to the following table for the maximum number
of units that can be driven by a single AC main power line.
max number of units
Device
powered by a single
230 V
Mugello-KH2 I
Mugello- KH3 I
Mugello- KH5 I
Never exceed the maximum number of units
powered by a single AC main power line.
12
KH3 I
600 W @ 8 Ω load,
600 W @ 8 Ω load,
Pink noise,
1/4 rated power
2
max number of units
powered by a single
16 A line
120 V
AC
AC
4 (3 joints)
2 (1 joint)
4 (3 joints)
2 (1 joint)
2 (1 joint)

230 V AC, 3-Phase Wye System

KH5 I
Distribute the loudspeaker loads across the three phases.
Pink noise,
1/4 rated power
G N L
click!
230V 3-Phase Wye
POWER DISTRO
20A line
Even if more units can be powered by the same line, try to keep
the load balanced by connecting the loudspeakers evenly
1
among the three phase lines.
max number of units powered by a single 230 V
Line-Neutral
230 V
AC
Never connect two lines to
the loudspeaker AC Main input.
Always be sure that each power cord is
connected to a single power line and the
common neutral and earth/ground.
L
L
1
2
3
4x KH2 I
4x KH3 I
16 A
(3 joints)
(3 joints)
Power
Power
Power
16 A line
AC
2x KH5 I
(1 joint)

Advertisement

Table of Contents
loading

Table of Contents