Installation
To pressurize the pedestal using the built-in
pump, proceed as follows:
To pressurize the pedestal manually, proceed as follows:
1.
Set the control valve (2) to the PUMP position.
2.
Ensure that the bottom stage is fully lowered and the
red bottom clamp (18) is applied. Remove the payload,
if fitted.
3.
Push down on the steering ring (20) against any residual
pressure and release the safety catch (7).
4.
Move the slide to the OFF position (O).
5.
Turn the steering ring to reveal the pressure gauge in
weight tray apperture.
6.
Using the steering ring (20), raise the top stage until fully
extended. Commence pumping by lowering and raising
the top stage over the upper half of its travel. When the
pressure gauge (3) begins to register, pump the top
stage over its full stroke. Stop pumping when maximum
working pressure is reached (indicated by the lower
edge of the red sector on the gauge) during the pumping
stroke.