Drive Unit Harness Installation

INVERTER
Plug 23 way connector into inverter.
Route encoder branch toward motor end of drive unit.
Route all other branches to most convenient location to make
remaining connections.
PWR/GND
Connect RED to 10A fused power that turns on with VCU
Wake.
Connect BLACK to chassis ground.
Do NOT power the inverter using the power/ground circuits
from an AEMnet cable.
Deutsch DT plug and terminals included in kit.