Regen Torque Limit Profile

The Control Board has a variable regen torque command limit profile programmed into it. The regen torque command limit
function compares the VCU's commanded regen torque value to the limit profile value and allows the lessor value to be the
actual regen torque allowed. The regen torque limit profile is shown below.
For example, if the VCU's commanded regen torque value is 50Nm at 8000 rpm, the actual regen torque allowed will be limited
to 40Nm. Alternatively, if the VCU's commanded regen torque value is 50Nm at 4000 rpm, the actual regen torque allowed will
be 50Nm.