AEM 30-8402 Installation Manual page 18

Tesla ldu inverter control board
Table of Contents

Advertisement

Shudder Compensation Enable EEPROM
Kp Shudder EEPROM
TCLAMP Shudder EEPROM
Shudder Filter Freq EEPROM
Shudder Speed Fade EEPROM
Shudder Speed Lo EEPROM
Shudder Speed Hi EEPROM
AEM Performance Electronics
2205 W 126th Street, Unit A
Hawthorne, CA 90250
Used to enable or disable shudder compensation.
Sets the control gain x 100 of the shudder compensation function. Default value
is 20 (parameter setting of 2000).
Defines the maximum amount of shudder compensation torque x 10 to be
applied. Default value is 19.1 (parameter setting of 191).
Defines the low-pass filter frequency x 10 used for shudder compensation
calculation. Default value is 3.0 (parameter setting of 30).
Defines the point in RPM where maximum shudder torque compensation is
applied for low RPM usage. Between this value and Shudder Speed Lo, full
shudder torque is applied. Must be lower than Shudder Speed Lo value. Default
value is 20.
Defines the start point in RPM where shudder torque begins to ramp out
(decrease). Shudder torque ramp out is reduced linearly between Shudder Speed
Lo & Shudder Speed Hi. Must be higher than Shudder Speed Fade but lower than
Shudder Speed Hi. Default value is 300.
Defines the end point in RPM where shudder torque is reduced to zero and
shudder compensation is turned off. Must be higher than Shudder Speed Lo.
Default value is 400.