D1. NEEDLE REPLACEMENT

Loosen the screw ① and remove the needle ②. Fix a new needle and turn it so that the hook scarf
③ is oriented according to detail
When needle type 134 is used, keep the screw ④ according to figure Ⓑ.
When needle type 134-35 is used, remove the screw ④ according to figure Ⓒ.
10
D MACHINE CONTROL
. Tighten the screw ①.