Graco HFRL Setup And Operation Manual page 85

Table of Contents

Advertisement

Error
Code Error Name Error Description
A hardware current fault has
Motor Over
A4N1
occurred causing a system
Current
shutdown
Red Blanket
A7A6
Control Fault
Blue Blanket
A7B5
Control Fault
Red Inline
A7A3
Control Fault
Blue Inline
A7B1
Control Fault
Unexpected current to
heater/chiller
Red Hose
A7A2
Control Fault
Blue Hose
A7B4
Control Fault
Red Chiller
A7A7
Control Fault
Blue Chiller
A7B8
Control Fault
No Red
A8A6
Blanket
Current
No Blue
A8B5
Blanket
Current
No Red Inline
A8A3
Current
No Blue Inline
A8B1
Current
No current to the conditioning
No Red Hose
zone
A8A2
Current
No Blue Hose
A8B4
Current
No Red
A8B7
Chiller
Current
No Blue
A8B8
Chiller
Current
A software error has occurred
Motor Over
A9C1
commanding too much
Current
current
The requested dispense
amount is below the minimum
B9C0
amount of the system (25% of
the combined pump volumes
is the minimum)
Small Shot
Request
B9C1
The requested dispense
amount (time/volume/weight)
is below the minimum amount
of the system
3A2175Z
Error
Type
Cause
Short circuit of motor
wiring
Alarm
Motor rotor has become
locked
Shorted Temperature
Alarm
Control Module
Tripped circuit breaker
Alarm
Low power
Cable unplugged/loose
power
Bad heater(s)
Bad Motor Control
Alarm
Module code
Pumps are defined with
the wrong size
Requested shot is below
the capabilities of the
current pump setup
Deviation
Short shot size
Appendix D - ADM Error Codes
Solution
Check wiring to the motor to ensure no bare wires
are touching and that no wires are shorted to ground
Unplug the directional valve (so pressure will not
build) and try to move the motor again. If this
succeeds then the power pack may need to be
replaced. If the motor is still unable to move, the
bearings or hydraulic pump have likely failed in the
motor and will need to be replaced.
If temperature rises for a zone that has been
disabled, replace Temperature Control Module
Visually check circuit breaker for a tripped condition
Measure voltage across input terminals on power line
filter. Voltage should measure between 190 and 264
Vac
Check for loose or disconnected wires or plugs
Measure resistance of heater(s)
Check for MCM software update, load latest MCM
software, if problem persists contact Graco
On the ADM go into the Setup screens to the System
screens then make sure that the pump sizes are
defined correctly
If the user has to be able to take the shot the system
must be fitted with smaller pumps
Increase the time/volume/weight of the shot
85