Appendix B - ADM Setup Screens Overview
Maintenance Screen
This screen shows shot number, sequence position,
dispense valve, and accumulator cycle counters. Press
and navigate to the drop down box. Press
scroll to a range of counters to view. Press
select the range of counters and display them on the
screen.
Counters may be erased individually. Navigate to the
counter you want to erase and press
each counter displayed on the page may be erased
simultaneously by pressing
68
and
again to
. Alternatively,
.
Supply Screen
This screen allows the user to specify the operating
parameters for off-board, integrated tanks and indicate
which positions have level sensors installed. See the
Tank Feed Systems manual for information about
installing level sensors, see Related Manuals on
page 3. The user may select from the following refill
settings: Disabled, Monitor, Manual, Auto Top-Off, Auto
Full-Volume.
NOTE: Use the "Disabled" setting if off-board tanks are
not installed.
The following describes system operation when each
tank mode is selected.
Disabled
Disables tank operation
Monitor
The top sensor generates a high level deviation
and the bottom sensor generates a low level
alarm
Refill is not supported, no button is provided on
the run screens to initiate refill
Errors will clear when the corresponding condi-
tion clears
Manual
The low level sensor will generate a low level
alarm
A button is provided to the user on the run
screens to instigate a manual refill operation at
any time
Manual refill will run until either the high level
sensor sees material, the user aborts the refill
via the refill button on the run screens, or the
refill time-out expires