Graco HFRL Setup And Operation Manual page 127

Table of Contents

Advertisement

Data Exchange
Pointer
Description
Designation
Blue Material Chiller
98
Zone, temperature
Heater Zones
102
Enabled Bit Masks
103
Heater Zones On/
Off Bit Masks
104
Current Tank Level
120
Status
121
Tank Filling Control/
Status, Red Tank
122
123
Tank Filling Control/
Status, Blue Tank
124
130
Ratio, Setpoint
132
Ratio, Actual
3A2175Z
Appendix I - Communications Gateway Module Installation Kit
Comments, Data Element Descriptions
Current Zone Actual Temperature, in 0.1 C
Bit 0 = Red Tank Zone Enabled (1) or Disabled (0).
Bit 1 = Blue Tank Zone Enabled or Disabled.
Bit 2 = Red Inline Heater Enabled or Disabled.
Bit 3 = Blue Inline Heater Enabled or Disabled.
Bit 4 = Red Hose Heater Enabled or Disabled.
Bit 5 – Blue Hose Heater Enabled or Disabled.
Bit 6 = Red Chiller Enabled or Disabled.
Bit 7 = Blue Chiller Enabled or Disabled.
Bit 0 = Red Tank Zone Turned ON (1)/ Off (0).
Bit 1 = Blue Tank Zone Turned ON/ Off.
Bit 2 = Red Inline Heater Turned ON/ Off.
Bit 3 = Blue Inline Heater Turned ON/ Off.
Bit 4 = Red Hose Heater Turned ON/ Off.
Bit 5 – Blue Hose Heater Turned ON/ Off.
Bit 6 = Red Chiller Turned ON/ Off.
Bit 7 = Blue Chiller Turned ON/ Off.
Least Significant Byte – Red Tank Level
nd
2
Significant Byte – Blue Tank Level
Level indications/ Byte:
1 = Material is below Low Level sensor.
2 = Material between Low and High Level (2
nd
3 = Tank Full (at 2
sensor, or above).
7 = Material at or above top sensor ("Report xxx High Level in bit
2" feature ON).
1 = Active Filling (Read) or Manual Fill Request (Write).
0 = Filling NOT Active (Read), or Abort Manual Fill (Write).
1 = Active Filling (Read) or Manual Fill Request (Write).
0 = Filling NOT Active (Read), or Abort Manual Fill (Write).
In 0.001:1 units of measure. So for instance, a value of 23680 =
23.680:1. Ratio may be inverted based on the setting of the
"Ratio:" control selection on the System #3 setup screen.
Ratios are either volumetric or weight depending upon the "Flow
Units" Selection on the ADM Advanced #2 setup screen.
In 0.001:1 units of measure. So for instance, a value of 23721 =
23.721:1. Ratio may be inverted based on the setting of the
"Ratio:" control selection on the System #3 setup screen. This
data is only valid if HFR or NVH has a Ratio Monitoring option
installed.
o
units
nd
) sensors.
Read/
Write
Read
Read
Write
Read
Read
Write
Read
Write
Read
Read
Read
127