System Screen 4
This screen will become visible if a Dynamic Mixer
Voltex is online. The screen allows the user to change
the settings of the dynamic mixer during a dispense
operation.
To change a setting, press
the corresponding control, and edit the control field
accordingly.
The Air Nucleation fields (top of screen) apply when the
function is turned ON by inserting a "X' into the "Air
Nucleation ON" check box entry. If active, the user can
select the ON time (when air is applied), off time (air
valve is closed) and delay the start of air application at
the start of the dispense. When the HFR is NOT
dispensing, no air is applied to the dynamic mixer.
The bottom controls allow the user to set the motor
speed and to enter a motor ramp up time to get to the
motor speed setting, which also applies to the deceler-
ation time after a dispense. If the "Complete Ramp Up
Before Dispensing" is checked, the HFR will wait for the
motor to complete its ramp time before the starting the
dispense and opening the dispense valve.
3A2175Z
soft key, navigate to
Appendix B - ADM Setup Screens Overview
Keyboard Screen
This screen is used to edit the A (Red) and B (Blue)
labels on the ADM. Use arrow keys to select the desired
letter and press
to accept the letter.