Components and Specifications
The following table describes the details of the two batteries that are used in the INFORMA
PMD-A device.
Details
Manufacturer
Part Number/Reference
Battery Specifications
Rated Capacity (minimum)
Operating Environment
Charging
Discharging
Storage Environment
Short Period less than 1
month
Long Period more than 3
months
Recommended storage
Notes
4S2P5SWB-SB
Rajamane Telectric
Private Limited
4S2P5SWB-SB-002
3.9 Ah with 0.5 C
Charging and 0.5 C
Discharging
0°C – +45°C,
Maximum 90% RH
-20°C ~ +60°C,
Maximum 90% RH
-20°C ~ +45°C,
Maximum 90% RH
-10°C ~ +30°C,
Maximum 90% RH
+15°C ~ +35°C,
Maximum 85% RH
•
If the battery is not
used for more than 3
months, then it has to
be discharged
completely and
recharged to 50%
power. If the
batteries are not
used for more than 6
months, there can be
a serious effect on
the battery life.
11
NH2054
INSPIRED ENERGY, Inc.
NH2054HD24
4.8 Ah
0°C to 45°C, <= 80% RH
-10°C to 50°C, <= 80% RH
-20°C ~ +60°C<= 80% RH
<21°C
•
The shelf life of the
battery is 6 months
when stored at 25°C.
•
If the storage
temperature exceeds
25°C over a 6-month
period, then the shelf
life of the battery is
reduced.
www.qualitrolcorp.com