Qualitrol 509-200 Operation Manual

Electronic cooling monitor for liquid-filled transformers

Advertisement

Electronic Cooling
Monitor for Liquid-Filled
Transformers
509-200
Operations Manual
IST-072-2

Advertisement

Table of Contents
loading

Summary of Contents for Qualitrol 509-200

  • Page 1 Electronic Cooling Monitor for Liquid-Filled Transformers 509-200 Operations Manual IST-072-2...
  • Page 2 QualiTROL Electronic Cooling Monitor for Liquid-Filled Transformers Operations Manual...
  • Page 3: Table Of Contents

    Overview ______________________________________________________________1 QualiTROL Electronic Cooling Monitor ................1 QualiTROL ..........................2 About This Manual ......................... 2 Controls, Indicators, and Modules _________________________________________3 Front Panel ..........................3 Modules ............................ 4 509-RTD Input Module ...................... 4 509-CT Input Module ......................4 509-AC Voltage Input Module ................... 4 509-Potentiometer Input Module ..................
  • Page 4 Viewing Channels (Viewing Mode Scrolling) ..............18 Menu Mode ........................18 Program Mode ........................20 Cooling System Monitor _________________________________________________20 Testing the System ......................... 22 Functional Specification _________________________________________________23 Appendix _____________________________________________________________24 Configuration Records __________________________________________________30 E C N - 2 7 4 3 3 A u g u s t 2 5 , 2 0 0 9...
  • Page 5: Overview

    QualiTROL Electronic Cooling Monitor The QualiTROL Electronic Cooling Monitor (ETM) for Liquid-Filled Transformers (Model #509-200 Series) is an Intelligent Electronic Device (IED). Combining microprocessor technology and advanced digital signal processing, to accurately assess the health, and performance of three phase or autotransformers.
  • Page 6: Qualitrol

    QualiTROL QualiTROL has been a leader in supplying pressure, liquid level, and temperature controls since 1945. An ISO 9001 system certified company, we are committed to providing you with quality and reliability, both in our products and in our service.
  • Page 7: Controls, Indicators, And Modules

    Set Point Indicators — A red LED illuminates to indicate that the set point for the relay indicated on the overlay has been exceeded. RS-232 Port —When used with the QualiTROL software, this port allows for the setup of all of the parameters of the Transformer Monitor. See Software...
  • Page 8: Modules

    Winding Currents, Motor Currents of LTC’s or fan currents. The inputs to the module is a clamp on CT provided by QualiTROL, that have an input range of 0- 5A, 0-10A, or 0-20A(other ranges available), and have an output of 0- 0.333VAC(to be used as the input to the CT Input Module).
  • Page 9: 509-Dc Voltage Input Module

    15000 ohms. Typically, the 25°mark on a liquid level dial is set to the center of the potentiometer range, and the high and low readings are simply ratios of the angular deflections from the “normal”(QualiTROL gauges use a 340 angular degree potentiometer on a 2:1 gear ratio from the dial travel to the potentiometer travel).
  • Page 10: Installation

    Location and Mounting Enclosure Style The QualiTROL Electronic Transformer Monitor is 3R enclosure style designed to be back-mounted on any smooth surface. Four 0.31 by 0.50 oval slots are provided for use with suitable fasteners. The Transformer Monitor requires an approximate area of 13"...
  • Page 11: Power Supply

    E l e c t r o n i c C o o l i n g M o n i t o r Rack Mount Style The QualiTROL Electronic Transformer Monitor is also designed to be rack mounted in a 19-inch transformer control cabinet. The Transformer Monitor is 3U high, approximately 10.5”...
  • Page 12 E l e c t r o n i c C o o l i n g M o n i t o r Figure 2. Power Supply Connection Figure 2a. Power Supply Connection for 5 KV impulse unit...
  • Page 13: Heater Option

    E l e c t r o n i c C o o l i n g M o n i t o r Figure 2b. Power Supply Connection for 19” Rack Mount unit The power supply has an internal removable fuse. If it becomes necessary to replace this fuse, it must be replaced with the same type and rating.
  • Page 14: Rtd Input Module

    This fuse is the responsibility of the installer. The rating of the heater is 120 volts AC and 100 watts. A 240 volt AC heater uses 2 of these heaters in series (a total of 200 watts). Qualitrol recommends a slow blow fuse rated at 1.25 or 1.5 Amps (600V).
  • Page 15: Ct Input Module

    Figure 6. AC Voltage Input Connections Potentiometer Input Module For each Potentiometer input module one standard potentiometer in the range of 0 to 15000 ohms (as supplied by various QualiTROL case assemblies) is required to measure Liquid Level, Flow, or Gas Accumulation. The Potentiometer input...
  • Page 16: Dc Voltage Input Module

    E l e c t r o n i c C o o l i n g M o n i t o r module must be calibrated on site. See the calibration section in the software manual for instructions on how to do this. The three conductors and the shield drain lead are connected to the Transformer Monitor as shown in Figure 7.
  • Page 17: Current Input Module

    E l e c t r o n i c C o o l i n g M o n i t o r Current Input Module The Current input Module is configurable to accept either a 0-1 ma DC or a 4-20 ma DC (SCADA type) signal.
  • Page 18: Dry Contact Closure Input Module

    E l e c t r o n i c C o o l i n g M o n i t o r Dry Contact Closure Input Module The Dry Contact (Switch) Closure Input Module is designed to detect the actuation or de-actuation of one dry (non-powered) switch contact.
  • Page 19: Remote Output Signals

    E l e c t r o n i c C o o l i n g M o n i t o r on Terminal Block TB1 see Figure 12 for the Enclosure and Panel Mount Units and see Figure 12a for the Rack Mount Unit. Refer to the software instruction manual (IST-073-3) for configuring the relays controlling signal, as failsafe/non-failsafe, time delay and other features.
  • Page 20: Communications

    E l e c t r o n i c C o o l i n g M o n i t o r The output signals are accessed on Terminal Block TB2 terminals 1 through 8 for the Enclosure and Panel Mount Units (see Figure 13) and TB2 terminals 9 through 16 for the Rack Mount Unit (see Figure 13a).
  • Page 21 E l e c t r o n i c C o o l i n g M o n i t o r used with the Qualitrol Remote Software Package and other available protocols. Refer to the 509 Software Manual (IST-073-3) and the 509 communications manual (IST-073-2) for a complete description of these features.
  • Page 22: Operation

    Viewing Mode Scrolling Viewing Channels ( Power up,<enter> The QualiTROL Electronic Transformer Monitor upon power being applied automatically begins to monitor the inputs and controls outputs based on the factory configuration specified by the customer. The display however, shows only time/date. It will remain in this state until the ENTER key is depressed, at which time the display will go into Viewing Mode scrolling and will Auto Scroll all of the parameters being monitored at a frequency of two seconds.
  • Page 23 ETM automatically reverts to Auto Scroll, or pressing the Menu button again reverts back to Viewing Mode scrolling. Qualitrol recommends resetting the maximum values immediately after setting up the unit to avoid any erroneous readings caused by the installation.
  • Page 24: Program Mode

    ID#. (This is the same ‘password’ that is used to enter the Customer Configuration section of the Qualitrol Remote Software Package; see manual IST-073-3). If you are not authorized to change these settings, press the Menu key to go back to Viewing Mode scrolling.
  • Page 25 E l e c t r o n i c C o o l i n g M o n i t o r traveling down the cooling mode column, the operator will view a window for each active cooling bank which reads: “COOLING CURRENT CMX <RESET>”.
  • Page 26: Testing The System

    E l e c t r o n i c C o o l i n g M o n i t o r Figure 16a. Front Panel Control for 19” Rack Mount unit Testing the System To perform a system confidence test, press and hold the TEST Button. Pressing the TEST key displays the setpoint source and value on the DISPLAY in one-second intervals.
  • Page 27: Functional Specification

    E l e c t r o n i c C o o l i n g M o n i t o r UNCTIONAL PECIFICATION Universal, 90-264 VAC, 47-63 Hz and 40-290 VDC; (< 18 watts) Power Supply: Front Panel Display: Type: 1 Easy to read 2-line, 16 character alphanumeric Liquid Crystal Display (LCD)
  • Page 28: Appendix

    E l e c t r o n i c C o o l i n g M o n i t o r PPENDIX...
  • Page 29 E l e c t r o n i c C o o l i n g M o n i t o r MENU SWITCH right right right right right right right ACTIVE RELAYS 05/24/2001 VIEW/RESET VIEW/RESET VIEW SETPOINTS COOLING MONITOR CHANGE SETTINGS DESCRIPTION...
  • Page 30 E l e c t r o n i c C o o l i n g M o n i t o r COOLING MONITOR MENU down/enter down/enter down/enter down/enter enter BOT OIL CHAN 8 BOT OIL 79.8 C CH1-CH6 2.3 C RUSH...
  • Page 31 E l e c t r o n i c C o o l i n g M o n i t o r down/enter down/enter down/enter down/enter down/enter enter INRUSH CURRENT ACTUATION SETPNT RUSH 37.2 AS RUNNING CURRENT RUSH LOWER SETPT COOLING MONITOR 32.9 AS 05000 #...
  • Page 32 E l e c t r o n i c C o o l i n g M o n i t o r RS-485...
  • Page 33 E l e c t r o n i c C o o l i n g M o n i t o r...
  • Page 34: Configuration Records

    E l e c t r o n i c C o o l i n g M o n i t o r Wiring Label (below) Rear Cover (below)
  • Page 35 E l e c t r o n i c C o o l i n g M o n i t o r ONFIGURATION ECORDS Parameter Name Comments/Range Parameter Name Set Point Input Module 1:____________________ ____________________ Relay 1:____________________ __________ Input Module 2:____________________ ____________________ Relay 2:____________________...
  • Page 36 For remote communications Qualitrol offers a 33.6K modem that interfaces directly with the auxiliary port of the 509. When used with the Qualitrol Remote Software package the user is capable of operating the 509 as if they were connected locally.

Table of Contents