Annex C; Installation Of Water-Cooled Units; Heat Sink And Operating Pressure; Materials In The Cooling Cicuit - KEB COMBIVERT F5 Instruction Manual

Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

C.

Annex C

C.1

Installation of water-cooled units

In continuous operation water-cooled inverters are operated with lower temperature than
air-cooled inverters. This has positive effects on lifetime-relevant components such as fan
and DC link circuit capacitors and power modules (IGBT). Also the temperature dependent
switching losses are positively effected. The use of water-cooled KEB COMBIVERT frequen-
cy inverters is offered in the drive technology, because there are process-caused coolants
available with some applications. The following instructions must be observed absolutely
when this units are used.
C.1.1

Heat sink and operating pressure

Design system
Extrusion casting heat
sink
Table 10:
The heat sinks are sealed with sealing rings and posses a surface protection (anodized) even
in the ducts.
Caution
In order to avoid a deformation of the heat sink and the damages involved, the indicated
max. operating pressure may not be exceeded briefly also by pressure peaks. Pay attention
to the guidelines 97/23/EG of pressure units.
C.1.2

Materials in the cooling cicuit

For the screw connections and also for the metallic articles in the cooling circuit which are in
contact with the coolant (electrolyte) a material is to be selected, which forms a small voltage
difference to the heat sink in order to avoid contact corrosion and/or pitting corrosion (elec-
tro-chemical voltage series, see table "Electro-chemical voltage series"). An aluminum screw
connection or ZnNi coated steel screw connection is recommended. Other materials must be
examined in each case before employment. The specific case of application must be checked
by the customer in tuning of the complete cooling circuit and must be classified according
to the used materials. With hoses and seals take care that halogen-free materials are used.
A liability for occuring damages by wrongly used materials and from this resulting corrosion
cannot be taken over!
Electro-chemical voltage series / standard potentials against hydrogen
Material
Lithium
Potassium
Calcium
Sodium
Material (voltage)
Aluminium (-1.67 V)
Heat sink and operating pressure
Deformation of the heat sink
generated Ion
Standard po-
Li
+
K
+
Ca
2+
Na
+
Max. operating pres-
sure
Material
tential
-3.04 V
Cobald
-2.93 V
Nickel
-2.87 V
Tin
-2.71 V
Lead
Annex C
Connecting duct
10 bar
00.00.650-G140
generated Ion
Co
2+
Ni
2+
Sn
2+
Pb
3+
Standard po-
tential
-0.28 V
-0.25 V
-0.14 V
-0.13 V
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f6

Table of Contents