2.5.3.

2.5.4. Ethernet Data Tagging Option

This option is used to help serial device to identify who is the received serial data's source; the
received serial data comes from Main Port or Aux Port.
© Copyright 2012 WIZnet Co., Ltd. All rights reserved.
Downloaded from
Elcodis.com
electronic components distributor

Packing Condition (Incoming serial data packing condition)

Type
Time
Data packing until the set time and then sent to server after the set time.
Size
Data packing until the set size and then sent to the server.
Character
Data packing until the set character and then sent to the server.
TCP/IP connection is discontinued if there is neither serial data nor network
Inactivity Time:
data during the set time.
-. Enable/Disable the H/W CMD switch pin.
H/W CMD switch
-. H/W CMD switch pin is the switch for sending commands from CPU to
WizFi630.
Type
Status
Enable or disable this option (Checked : Enable, Un-Check : Disable)
Before sending data from Main port to serial port, WizFi630 added a TAG in
the front of payload.
Main Port
For example:
In-come LAN Data : "abcdegf"
Output data to Serial Port : "!MAIN!abcdegf"
Before sending data from Aux port to serial port, WizFi630 added a TAG in
the front of payload.
Aux Port
For example:
In-come LAN Data : "abcdegf"
Output data to Serial Port : "!AUX!abcdegf"
Description