Repair/Parts List SaniForce® 1040 Air - Operated 3A6780D High Sanitation Diaphragm Pump For use use in in in sanitary sanitary applications. sanitary applications. applications. For professional professional professional use use only. only. only. Important Important Important Safety Safety Safety Instructions Instructions Instructions Read all warnings and instructions in this manual and related...
Warnings Warnings Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings.
Page 4
Warnings WARNING EQUIPMENT MISUSE MISUSE HAZARD HAZARD EQUIPMENT EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component.
Configuration Number Matrix Configuration Number Number Matrix Matrix Configuration Configuration Number Matrix Check the identification plate (ID) for the Configuration Number of your pump. Use the following matrix to define the components of your pump. When you receive your pump, record the 9 character part number found on the shipping box (e.g., SP1B.0018): _____________ Also record the configuration number on the pump ID...
Use the Online Online Online Diaphragm Diaphragm Diaphragm Pump Pump Pump Selector Selector Selector at at at www.graco.com www.graco.com www.graco.com. . . To locate, search on selector selector selector. To Order Order Replacement Replacement Parts Parts Order Replacement Parts Please...
Troubleshooting Troubleshooting Troubleshooting Troubleshooting • Follow the Pressure Relief Procedure, page 9 • Check all possible problems and causes before before checking or servicing the equipment. disassembly. Problem Cause Solution Problem Problem Cause Cause Solution Solution Pump cycles at stall or Worn checks or seating surfaces.
Page 8
Troubleshooting Problem Problem Problem Cause Cause Cause Solution Solution Solution Fluid in exhaust air. Diaphragm ruptured. Replace. See standard or Overmolded repair procedure. Loose diaphragm plate. Tighten or replace. See standard or Overmolded repair procedure. Pump exhausts excessive Worn air valve block, plate, pilot Repair or replace.
Page 9
Repair Repair Repair Repair Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure 1. Follow the Pressure Relief Procedure, page 9 2. With a Torx (T20) screwdriver or 7 mm (9/32 in.) Follow the Pressure Relief Procedure socket wrench, remove the six screws (107), air whenever you see this symbol.
Page 10
Repair 5. Inspect the valve plate (110) in place. If 3. Install the u-cups (106) onto the actuator pistons damaged, use a Torx (T20) screwdriver or 7 mm (E) and insert the travel restrictors (2) from the (9/32) in.) socket wrench to remove the three diaphragm install tool kit into the actuator pistons screws (107).
Repair Reassemble Air Air Valve Valve Reassemble Reassemble Valve 6. Grease the lower face of the pilot block (116) and install so its tabs snap into the grooves on the ends of the pilot pins (112). 1. If the center section was disassembled to replace the bearings (113, 115), complete the center section repair before continuing with the air valve reassembly.
Page 12
Repair Check Valve Valve Repair Repair Check Check Valve Repair 6. To continue disassembly, see Disassemble the Standard Diaphragms, page NOTE: Kits are available for new check valve balls in NOTE: NOTE: a range of materials. Gasket kits also are available. Reassemble Reassemble Reassemble the...
Repair Standard Diaphragm Diaphragm Repair Repair Standard Standard Diaphragm Repair NOTE: NOTE: NOTE: Overmolded diaphragms are covered in 5. Disassemble the free diaphragm assembly. Overmolded Diaphragm Repair, page 6. Remove plate (12) with bolt (14) installed, diaphragm (10), backer (11) if present, and plate Tools Required Required Tools...
Page 14
Repair Reassemble the the Standard Standard Diaphragms Diaphragms Reassemble Reassemble Standard Diaphragms 4. Grease the length of the diaphragm shaft (24), NOTICE NOTICE NOTICE and slide it through the housing (101). After reassembly, allow the thread locker to cure 5. Assemble the other diaphragm assembly to the for 12 hours, or per manufacturer’s instructions, shaft as explained in step 2.
Page 15
Repair Overmolded Diaphragm Diaphragm Repair Repair Overmolded Overmolded Diaphragm Repair Tools Tools Tools Required Required Required 6. Pull the opposite diaphragm assembly and shaft (24) out of the center housing (101). Hold the • Torque wrench shaft flats with a 19 mm open end wrench and remove the diaphragm and air side plate from •...
Page 16
Repair Reassemble the the Overmolded Overmolded Diaphragms Diaphragms Reassemble Reassemble Overmolded Diaphragms 3. Screw assembled diaphragm assembly into shaft NOTICE NOTICE NOTICE (24) and hand tighten. After reassembly, allow the thread locker to cure 4. Grease the length of the diaphragm shaft (24), for 12 hours, or per manufacturer’s instructions, and slide it through the housing (101).
Repair Center Section Section Repair Repair Center Center Section Repair Tools Tools Tools Required Required Required 5. Use a 10 mm socket wrench to remove the screws (104) holding the air covers (103) to the • Torque wrench center housing (101). •...
Page 18
Repair Reassemble the the Center Center Section Section Reassemble Reassemble Center Section 1. Install the shaft u-cups (106) so the lips face 5. Align the air cover (103) so the pilot pin (112) fits of the housing. in the middle hole (M) of the three small holes near the center of the cover.
Parts Parts Parts Parts SP1B.xxxx model shown 3A6780C Springer Pumps, LLC Tel: 866-777-6060 Website: www.springerpumps.com Fax: 866-777-6383 Int'l: +001 267 404 2910...
Page 20
Parts Parts/Kits Quick Quick Reference Reference Parts/Kits Parts/Kits Quick Reference Use this table as a quick reference for parts/kits. Go to the pages indicated in the table for a full description of kit contents. Qty. Qty. Ref. Part/Kit Description Description Description Qty.
Page 21
Parts Center Section Section Center Center Section Sample Configuration Number Pump Wetted Drive Center Section Manifolds Seats Checks Seals Certifica- Model Section and Air Valve aphragms tion 1040 SP1A SP1A SP1A 3A6780C Springer Pumps, LLC Tel: 866-777-6060 Website: www.springerpumps.com Fax: 866-777-6383 Int'l: +001 267 404 2910...
Page 22
Parts Part Description Part Description Part Part Description Description Part Part Description Description HOUSING, air motor 108† 157628 O-RING 25P123 COVER 25P124 25P128 S01A, SP1A GASKET, air cover kit; pkg 25P129 S03A, SP3A of 2 110† 15H178 PLATE, valve 25P113 use with PS diaphragms 188609 BEARING, shaft...
Page 23
Parts Diaphragms Diaphragms Diaphragms Sample Configuration Number Pump Wetted Drive Center Section Manifolds Seats Checks Diaphragms Seals Certifica- Model Section and Air Valve tion 1040 SP1A Bolt- - - Through Through Diaphragm Diaphragm Kits Kits Overmolded Diaphragm Diaphragm Kit Bolt Bolt Through Diaphragm...
Technical Data Technical Technical Technical Data Data Data SaniForce SaniForce 1040 SaniForce 1040 Air 1040 Air- - - Operated Operated Operated Double Double Diaphragm Double Diaphragm Pump Diaphragm Pump Pump Metric Metric Metric Maximum fluid working pressure 120 psi 0.8 MPa, 8 bar...
Page 25
Technical Data Fluid Fluid Fluid Temperature Temperature Temperature Range Range Range NOTICE NOTICE NOTICE Temperature limits are based on mechanical stress only. Certain chemicals will further limit the fluid temperature range. Stay within the temperature range of the most-restricted wetted component. Operating at a fluid temperature that is too high or too low for the components of your pump may cause equipment damage.
Page 26
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.