Air-operated high sanitation diaphragm pump (26 pages)
Summary of Contents for Graco SaniForce STU.A09GAB2AB1C21
Page 1
Repair/Parts SaniForce® Sanitary Sanitary Tote Tote Unloader Unloader SaniForce® SaniForce® Sanitary Tote Unloader 3A5417G (STU) (STU) (STU) For use use with with food food grade grade bulk bulk supply supply of of of medium medium to to to high high viscosity viscosity product.
Warnings Warnings Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings.
Page 4
Warnings WARNING SKIN SKIN INJECTION SKIN INJECTION INJECTION HAZARD HAZARD HAZARD High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical surgical treatment.
Page 5
Warnings WARNING EQUIPMENT EQUIPMENT EQUIPMENT MISUSE MISUSE HAZARD MISUSE HAZARD HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component.
Configuration Matrix Configuration Matrix Matrix Configuration Configuration Matrix Check the identification plate (ID) for the Configuration Number of your system. Use the following matrix to define the components of your system. STU A01AAA1AA1C21 A01AAA1AA1C21 A01AAA1AA1C21 Sample Configuration Configuration Number: Number: Sample Sample Configuration...
Page 7
Configuration Matrix Approvals Approvals Approvals All models are rated and are FDA compliant. ATEX models with piston pumps II 2 GD are rated Ex h IIA T4 Gb X Ex h IIIB T100°C Db X ATEX T-code rating is dependent on the temperature of the fluid being pumped.
Troubleshooting Troubleshooting Troubleshooting Troubleshooting 1. Follow the Pressure Relief Procedure in the operation manual before servicing the equipment. 2. Check all possible problems and causes before disassembling the system. Problem Cause Solution Problem Problem Cause Cause Solution Solution Ram plate will not rise. Ram Up air pressure set too low.
Parts Plates Plates Plates Sample Configuration Number STU.A01BAB1AA0C21 Sanitary Tote Seal Seal Unloader Frame Pump Plate Type Material Control Accessories Wash Bin Certification B B B Ref. Ref. Ref. Part/Kit Part/Kit Part/Kit Description Description Description Qty. Qty. Qty. Pump/Plate Pump/Plate Configuration Pump/Plate Configuration Configuration...
Page 25
Parts Plate Plate Plate Kits Kits Kits These kits contain parts 7.1-7.10. Pump/Plate Codes Codes Kit Part Part Part Bin Type Type Type Pump Pump Pump Plate Plate Plate Dim Dim A A A Plate Plate Plate Dim Dim B B B Pump/Plate Pump/Plate Codes...
Parts Inflatable Seals Seals Inflatable Inflatable Seals In order to determine the correct seal to order, refer to the table below for applicable configuration number data to use for your system. Sample Configuration Number STU.A01BAB1AA0C21 Sanitary Tote Seal Seal Unloader Frame Pump Plate Type Material...
Parts Manual Control Control Manual Manual Control Sample Configuration Number STU.A01BAB1AA0C21 Sanitary Tote Seal Seal Unloader Frame Pump Plate Type Material Control Accessories Wash Bin Certification 1 1 1 Control Part Part Part Title Title Title Description Description Description Refer to to to manual: manual: Control Control...
Parts Electro - - - Pneumatic Pneumatic Control Control Electro Electro Pneumatic Control Sample Configuration Number STU.A01BAB2AA0C21 Sanitary Tote Seal Seal Unloader Frame Pump Plate Type Material Control Accessories Wash Bin Certification 2 2 2 Control Part Title Description Refer to to to manual: manual: Control Control...
Parts Liner Clamp Clamp Liner Liner Clamp Sample Configuration Number STU.A01BAB2AA0C21 Sanitary Tote Seal Seal Unloader Frame Pump Plate Type Material Control Accessories Wash Bin Certification Bag Liner Liner Clamp Clamp Aseptic Liner Liner Clamp Clamp Liner Clamp Aseptic Aseptic Liner Clamp Acces-...
Parts Wash Bin Wash Wash Sample Configuration Number STU.A01BAB2AA0C21 Sanitary Tote Seal Seal Unloader Frame Pump Plate Type Material Control Accessories Wash Bin Certification 1 1 1 Wash Part Title Description Wash Wash Part Part Title Title Description Description Refer Refer Refer to to to manual: manual:...
Technical Data Technical Data Data Technical Technical Data SaniForce SaniForce STU SaniForce Metric Metric Metric Maximum working fluid pressure See pump manual Compressed air requirement 60-100 psi 0.41-0.7 MPa, 4.1-7 bar Pressure ratio See pump manual Air consumption See pump manual. Multiply by number of pumps Flow rate @ 60 cpm See pump manual.
Page 32
California Proposition 65 Fluid Temperature Temperature Range Range Fluid Fluid Temperature Range NOTICE NOTICE NOTICE Temperature limits are based on mechanical stress only. Certain chemicals will further limit the fluid temperature range. Stay within the temperature range of the most-restricted wetted component. Operating at a fluid temperature that is too high or too low for the components of your pump may cause equipment damage.
Page 34
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts.