25) Using the rope and the cable, move the Inclinometer Probe to the far end of
the casing, stopping when the ferrule marking the correct distance (depth if
compared to the vertical system) is reached. Keep tension on the rope and
cable at all times to avoid any slack.
26) Set the cable ferrule into the cable gate (with tension applied to the "tension
end" of the pull rope) at the depth you need to start your survey from.
27) Apply a very light tension to the rope, to keep the ferrule in place within the
cable gate. The tension should be constant otherwise the probe will be
shaken, and the reading will not be accurate. (The software will not allow a
reading to be taken if the probe is not stable. If this occurs, slightly reduce the
tension on the rope, being mindful that there may be slight movement in the
probe if the casing slopes downhill in either direction). It may take a few
minutes for the temperature of the probe to stabilise, it is good practice to
allow a period of time for the temperature of the system to equilibrate if the
probe has for example been kept in a warm car and the outside temperature
is cold.
28) Take the reading using the IncloPRO software. Linking the Android device to
the reel can be found in section 8.1 with details of the software use in 9.
USING INCLOPRO SOFTWARE APPLICATION (ANDROID).
29) Once the reading has been taken using the software, the probe can be moved
up to the next ferrule and the process repeated until the probe reaches the
access end of the casing.