Electrical Box - Daikin ARKC12RV2S Service Manual

Removal procedure
Table of Contents

Advertisement

Electrical Box

3. Electrical Box
Warning
Step
1
Remove the 7 screws
on the terminal board
and disconnect the
connecting wire and
power supply wire.
2
Remove the 3 screws,
and then the wire
fixture.
3
Disconnect the
connector [S80].
4
Disconnect the
connector [S20].
6
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Terminal board
Connecting
wire
[S80]
[S20]
Wire fixture
Power supply wire
(R22390)
(R22391)
(R22392)
Si001560EB
Points
[S80]: four way valve coil
The cooling only models
have no harness for [S80].
[S20]: electronic expansion
valve coil
Removal Procedure