Pcb - Daikin ARKC12RV2S Service Manual

Removal procedure
Table of Contents

Advertisement

Si001560EB

4. PCB

Warning
Step
1
Remove the 2 earth/
ground screws.
2
Remove the 3 screws
of the PCB.
3
Unfasten the 2 hooks
and remove the PCB.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Earth/ground screw
PCB
Projection
(R23997)
Hook
(R22406)
Hook
(R22407)
PCB
Points
Some models do not have a
ferrite core on the earth/
ground harness.
When reassembling, make
sure to fit the 2 projections to
the PCB.