Fig. 37: Control Dimension X; Table 44: Control Dimension X - ABB PT004165 Operation Manual

Table of Contents

Advertisement

Operation Manual / Power2 850-M / High-pressure stage
9 Disassembly and assembly / 9.11 Installing the cartridge group
Control dimension after installing cartridge group
CAUTION
Control dimension outside the tolerance value
If the control dimension is out of tolerance, the cartridge group has not
been correctly installed and can be the cause of serious damage to the ma-
chine or property.
Remove and reinstall the cartridge group.
u
Always replace jammed gasket rings with new ones.
u
If the control dimension is still out of tolerance, contact a Turbo Systems
u
service station.
Fig. 37: Control dimension X
After installing the cartridge group, the control dimension (X) must be measured.
Table 44: Control dimension X
© Copyright 2022 ABB. All rights reserved.
Control dimension X
[mm]
49.0 ±0.2
HZTL4063_EN