Operation Manual / Power2 850-M / High-pressure stage
6 Operation and service / 6.2 Service work
6.2

Service work

Service work includes visual controls, monitoring, measuring and inspection as well as func-
tional checks. Service work enables the detection and rectification of changes to the low and
high-pressure stage and ensures full operability of the low and high-pressure stage.
CAUTION
Service intervals
Service work on the low-pressure and high-pressure stage that is omitted or
performed too late can cause excessive contamination and wear as well as
operating failures.
Carry out the service work at the specified time intervals.
u
CAUTION
Specific service interval
Exceptional stresses such as a high number of starts and stops, harsh envir-
onmental conditions, poor fuel quality or high system vibrations can lead to
untimely machine damage even if the prescribed service intervals are ob-
served.
Agree on a specific service interval with Turbo Systems.
u
To prevent machine damage caused by ageing and downtime, we recommend having an in-
spection carried out by a Turbo Systems service station no later than 5 years after the last
service.
6.2.1
Service work every 25 ... 50 hours
Visual check for air, exhaust gas, water and oil leaks.
u
Record operating data and enter in the engine logbook.
u
In case of deviations, determine the cause.
u
6.2.2
Service work at 100 hours after commissioning
Clean or replace the oil filter located in the supply pipe to the low-pressure and high-pres-
u
sure stage while the engine is stopped.
6.2.3
Service work according to instructions of enginebuilder
Clean or replace the oil filter located in the supply pipe to the low-pressure and high-pres-
u
sure stage while the engine is stopped.