Removing The High-Pressure Stage; Fig. 12: Suspension Of Complete High-Pressure Stage - ABB PT004165 Operation Manual

Table of Contents

Advertisement

Operation Manual / Power2 850-M / High-pressure stage
3 Removal and installation / 3.2 Removing the high-pressure stage
3.2

Removing the high-pressure stage

CAUTION
Tilting of high-pressure stage and leaks at the bellows
The high-pressure stage may not be transported or put down with the air
suction branch and the bellows fitted.
The air suction branch / bellows combination must be transported and
u
fitted separately.
Fig. 12: Suspension of complete high-pressure stage
Remove insulation.
u
Disconnect all gas, air, water and oil pipes in accordance with the enginebuilder's instruc-
u
tions.
Unplug the cable connector at the speed sensor.
u
Remove the air suction branch together with the bellows
u
suction branch
→69).
Check lifting gear.
u
Attach one lifting gear to the two suspension points of the bearing casing and one lifting
u
gear to the support.
Loosen fixing screws at foot and support.
u
Lift the high-pressure stage from the engine and put it down.
u
Cover the oil connection.
u
© Copyright 2022 ABB. All rights reserved.
(see Fig. 22: Removing the air
HZTL4063_EN
Rev.F