Table 16: Cleaning Parameters Power2 Lp; Table 17: Cleaning Parameters Power2 Hp - ABB PT004165 Operation Manual

Table of Contents

Advertisement

Operation Manual / Power2 850-M / High-pressure stage
7 Periodic maintenance / 7.2 Cleaning the compressor during operation
7.2.3
Wet cleaning with direct water supply
Prerequisites
Do not clean the compressors of the different high and low-pressure stages at the same
time, but one after the other.
On V-engines with several low-pressure and/or high-pressure stages per engine, Turbo Sys-
tems recommends the parallel cleaning of the LP compressors as well as the parallel clean-
ing of the HP compressors. This cleaning process is faster and reduces the risk of surging of
the low-pressure and high-pressure stages.
Wet cleaning operations for compressor with direct water supply
Trigger water injection according to the instructions of the enginebuilder.
u
Observe water pressure before connection to pressure stage.
u
Operate engine for at least five additional minutes after cleaning.
u
The cleaning process can be repeated up to three times.
The success of the cleaning can be recognised based on the charging pressure or the ex-
haust gas temperature.
If the cleaning is still unsuccessful after three processes and the engine values are unsatis-
factory, it is recommended to have the low-pressure and / or high-pressure stage checked
and cleaned by a service station.
Cleaning parameters for each compressor
Power2
850 LP
Table 16: Cleaning parameters Power2 LP
Power2
850 HP
Table 17: Cleaning parameters Power2 HP
* Compressor inlet pressure depending on the operating point
© Copyright 2022 ABB. All rights reserved.
Engine load
Water pressure
50 ... 100 %
Engine load
Water pressure
50 ... 100 %
HZTL4063_EN
Water injection time
[bar]
3
Water injection time
[bar]
p
* + 3
VE
[s]
10
[s]
10
Rev.F
March 2022