ComAp InteliDrive Mobile Global Manual page 168

Expendable automotive engine controller
Table of Contents

Advertisement

Source: Log Bout
Alarm Blink
Related FW
2.6.0
Comm object
275
Description
Function is based on Binary output COMMON ALARM - stays closed when any alarm is active (at least one
item in Alarm list) and opens for 2 sec when any new Alarm is activated. The first activation is delayed 2 sec.
No Fault reset influence when at least one alarm is active. Output opens when Alarm list is empty.
6 back to List of LBO
Alarm BlinkAct
Related FW
2.6.0
Comm object
278
Description
Alarm indication:
Output starts switching (blinking 0.5 / 0.5 sec from opened or closed state) when any new alarm
comes
Output stays closed after Fault reset when any alarm is still active
Output opens after Fault reset when no alarm is active
6 back to List of LBO
Alarm
Related FW
2.6.0
Comm object
2
Description
The output closes if any alarm is activated and opens after Fault reset even if the Alarm is still active.
6 back to List of LBO
BO 1/2 Fail
Related FW
2.6.0
Comm object
352
Description
Indication of Binary output 1 and/or Binary output 2 fail or Broken wire detection.
6 back to List of LBO
BO 3/4 Fail
Related FW
2.6.0
Comm object
353
Description
Indication of Binary output 3 and/or Binary output 4 fail or Broken wire detection.
6 back to List of LBO
ID-Mobile Global Guide
Related applications
Related applications
Related applications
Related applications
Related applications
AMF, MRS
AMF, MRS
AMF, MRS
AMF, MRS
AMF, MRS
168

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the InteliDrive Mobile and is the answer not in the manual?

Table of Contents