Display - RME Audio ADI-2 Pro SE User Manual

Hide thumbs Also See for ADI-2 Pro SE:
Table of Contents

Advertisement

Toggle Ph/Line
OFF, 1/2, 3/4, 1/2+3/4, All Plugged, Line/Digital. Default: OFF. Activates the ability to toggle mute
between Phones Out, rear Line Out and digital outputs. Pushing the VOLUME knob for half a
second will then switch between loudspeakers connected to the rear and phones plugged into the
front. This function can also be controlled by one of the four function keys via Remap Function
Keys. All Plugged only incorporates the phones output where a plug is detected. Line/Digital
switches between analog Line Out and digital outputs, with Mute vs TRS active also between
Phones and digital outputs.
Mute v. TRS 1/2
ON, OFF. Default: ON, but grayed out. As soon as a plug is detected in PH 1/2 the rear outputs
1/2 are muted. Note: This function requires Dual Phones to be ON to become accessible. With
Mute v. TRS 1/2 ON the channels Phones 1/2 and Line Out 1/2 have separated settings. Although
both outputs alternately play back the same signal, all settings (Settings, EQ, BT) can be different,
and are separately stored in the background.
Mute v. TRS 3/4
ON, OFF. Default: ON. If set to ON a plug detected in PH 3/4 mutes the rear outputs 1/2.

14.1.6 Display

Display Mode
Available settings are: Default, Dark. The dark scheme in-
verts the white background and black numbers/text to black
background and light-grey numbers/text.
Meter Color
Green, Cyan, Amber, Monochrome, Orange, Red. Default:
Cyan. Color of the level meters for PCM and DSD mode.
Hor. Meter
The horizontal stereo level meter below the Analyzer can show the peak level before all DSP
processing (Pre, equals the current input level from USB playback and SPDIF In), after all pro-
cessing including volume control (Post), or both at the same time (Dual, default). The outer thin
line is the Pre level. In Dual mode the peak values to the right refer to Post level. Post FX dBu
shows numerical values referenced to dBu.
AutoDark Mode
OFF, ON. Automatically turns off all LEDs and the display (exception: Standby button) after 10
seconds of user inactivity. A key press and turning an encoder will temporarily activate LEDs and
display again. Info and warning messages are shown for 3 seconds.
Show Vol. Screen
ON, OFF. Default: ON. When turning the VOLUME knob the Volume screen is shown.
LCD Brightness
Adjustable from 20% to 100%. Default is 80%.
LCD Tint Control
Adjustable from -8 (yellow) to 8 (blue). Enables compensation of the display's colour deviation as
well as suiting the user's taste.
Lock UI
OFF, Remote, Keys, Keys+Remote. Locks the keys on the device (Keys), the remote control
(Remote) or both (Keys+Remote). Only VOLUME remains operable. To unlock, press and hold
encoder 1.
Encoder Filter
Default 1, 1 to 5. Jumping or backward running encoders can in most cases be used normally
again with the setting 3.
User's Guide ADI-2/4 Pro SE - v 1.0
32

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adi-4 pro se

Table of Contents