Section 4..................................................................Transport and Storage
4. STORAGE
Store the pump in location away from vibration and Dampness
4.1 Short Term Storage (Maximum 6 months)
If at all possible, the pump and its component parts should be stored indoors where they will be
protected from the elements. In no case should any pump element be subjected to extended periods
of submergence or wetting prior to start up. If it is not possible to store the pump and its components
indoors, precautions must be taken to protect them from the elements. Regardless of whether storage
is indoors or outside, the storage area should be vibration free. All boxes marked for indoor storage
should be stored indoors. When stored outdoors the pump and its components should be protected
from dirt, dust, rain, snow, or other unfavorable conditions by heavy plastic sheets, canvas, or other
suitable coverings. All equipment must be placed upon skids or blocks to prevent contact with the
ground and surface contaminants. Equipment must be adequately supported to prevent distortion and
bending. The pump shaft should be rotated, in the direction of rotation, at least 1 and 1/4 turns each
week during the storage period and any other periods of standby.
4.2 Long Term Storage
Depending on the length of time the equipment has been stored, and the type of storage provided
(i.e. Indoor: heated, unheated, earth floor, concrete floor. Outdoors: under roof, no roof, waterproof
coverings, on concrete, on earth), the pump will require a full inspection before the scheduled
installation date. This could include a visual inspection, partial or even a full dismantling of the
equipment. This should be carried out by qualified personnel, or a Pentair Southern Cross
representative. Dismantling the equipment may require the replacement of gaskets and seals. All
costs involved during the inspection, dismantling, replacement of parts and reassembly will be at
the expense of the customer. All necessary labour, tools and cranes required will be supplied by the
customer.
5. PACKAGING
Goods are packed for Interstate Land Transport only unless otherwise specified in the contract. If
transporting the goods overseas from buyers' location, they should be repacked appropriately.
Store the pump in a clean, dry location away from vibration.
Leave piping connection covers in place to keep foreign
material out of pump casing. Turn pump at intervals to
prevent brinelling of the bearings and seal faces, if fitted, from
sticking. Electric Motors (Pump Driver) should not be stored
in damp places without special protection (Refer to Motor
manufacturers instructions). The pump may be stored as
above for up to 6 months.
17
ISO PRO Centrifugal Pump