Design Of Major Parts - Pentair ISO PRO Installation, Operation And Maintenance Manual

Iso 5199 standard centrifugal pumps
Table of Contents

Advertisement

Day of Month
Month
01 to 31
A = January
ISO PRO Centrifugal Pump
B = February
C = March etc
2. Size
Section 2.......................................................................Pump Construction
eg:- 60x40-315
3. Impeller Diameter (mm)
eg:- 310
2.4 Model
"Item Code" of pump (from work order)
4. Model
eg:- MHB15C-F
Starline
PRHG3A
ISO PRO
2.5 Construction Code
PSFA1A
ISO Sovereign
This code defines construction material of various components in the pump.
AUSGD2E
AUS ISO
5. Construction Code
eg:- CZ5CMW
Casing/Backplate
Impeller Material
C - Cast Iron
C - Cast Iron
S - 316 Stainless
S - 316 Stainless
Z - Zinc Free Bronze
Z - Zinc Free Bronze
N - Ni Resist
N - Ni Resist
A - ADI
A - ADI
M - SGI (Malleable)
M - SGI (Malleable)
P - Alum Bronze
P - Alum Bronze
R - 2RK65
R - 2RK65
X - Exotic Material
X - Exotic Material

3. DESIGN OF MAJOR PARTS

3.1 Pump Casing (All Pump Types)
The Casing type is Foot Mounted, ISO vertical, Centerline, End Suction, Top Discharge, one piece
solid construction. A wear ring may be mounted in the casing to provide a close running clearance with
the impeller Neck ring.
3.2 Impeller (All Models)
The impeller is a single suction, radial / Mixed flow, closed design. The impeller is dynamically
balanced, keyed to the shaft. Renewable Neck rings can be press fit onto the impeller hubs (front and
back) where needed. Double curvature impeller blades, provide highly efficient suction performance,
higher speed capabilities and greater performance for reduced running costs and maintenance.
Impeller is taper mounted and keyed to shaft and secured by Lock Washer and Impeller nut for
positive locking.
3.3 Lock Washer (All Pump Types)
Lock washers are assembled between impeller and impeller nut. These Lock washers are
manufactured by Nord-Lock. NORD-LOCK is a pair of washers with a wedge-locking action meeting
DIN 25201 which is a unique method using tension instead of friction. The NORD-LOCK bolt securing
system uses geometry to safely lock impeller onto the pump shaft.
3.4 Shaft (All Pump types)
The shaft is made of high grade stainless steel. It is precision machined over its entire length and has
generous fillet radii at each change of section to reduce stress concentrations. Water slinger prevents
intrusion of pumped fluid into shaft bearing.
3.5 Heavy Duty Bearing Housing
The pump has positively located dual bearings.
Year
Assembly Loca on
2010
A = Toowoomba
P = Perth
Su
flange
Discharge flange
X
nominal bore
nominal bore
Actual outside diameter of the impeller in millimetres (If blank,
the impeller is full-size)
"Item Code" of pump (from work order)
Materials pump constructed from
Shaft Material
Seal Type
2 - 420 Stainless
C - Nitrile Mech. Seal
3 - 316 Stainless
V - Viton Mech. Seal
4 - 431 Stainless
E - Empty Pack Gland
5 - 316 Cast Stainless
P - Packed Gland
6 - SAF2205
H - Hard Faced Seal
X - Exotic Material
S - Single Cartridge Seal
D - Double Cartridge Seal
X - Special
Pump Series Number
3rd pump
assembled on this day
-
Impeller nominal
outside diameter
C
Z
5
C
M
W
Bearing Type
G - Grease Lubed
M - Motor Pump
O - Oil Lubed
P - Prepacked
10
AUS ISO
ISO SOV
ISO PRO
X
Bearing Housing
Wear Rings
W - Wear Rings Fitted
X - Denotes Mk2 bearing
housing of 2013
Leave blank if none fitted)
(leave blank for older housing)
03K2013A06
100X65-250
200
AUSGD2BE CZ2CP X
03K2013A09
50X32-200
180
PSFA1A CC4CP X
03K2013A01
150X125-315
304
PRHG3A CC4XOWX

Advertisement

Table of Contents
loading