WEST POS-124-U-PFN Technical Documentation Manual page 41

Table of Contents

Advertisement

Typical settings:
Command
AIN_1:X
1000
1000
AIN_1:X
10
OR
AIN_1:X
1000
800
AIN_1:X
10
OR
AIN_1:X
1000
400
AIN_1:X
20
OR
AIN_1:X
2000
1600
OR
AIN_1:X
1250
1000
Page 41 of 70
Input
0 V
0... 10 V
8
1000 V
1... 9 V
1000 V
4
500 V
0,5... 4,5
V
500 V
16
2000 C
4... 20mA
2000 C
2000 C
Description
Range: 0... 100 %
Range: 0... 100 %; 1 V = 1000 used for the offset and
gained by 10 / 8 (10 V divided by 8 V (9 V -1 V))
Range: 0... 100 %; 0,5 V = 500 used for the offset and
gained by 10 / 4 (10 V divided by 4 V (4,5 V -0,5 V))
Range: 0... 100 %
The offset will be compensated on 20 % (4 mA) and the
signal (16 mA = 20 mA – 4 mA) will be gained to 100 %
(20 mA).
Each of this parameterization for 4... 20 mA is setting the
range to 0... 100 %.
POS-124-U
24.01.2022

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pos-124-u-etcPos-124-u-pdp1

Table of Contents