DI must be in the E24V and EGND power system, otherwise there will be abnormal .
(2) MDI connector
Description: Connection to MDI unit.
Connector description: 2.54mm 26PIN box header connector.
(3) OP connector
Description: Connection to OP unit. Provide 5V level DI:80 points DO:80 points.
Connector description: 2.54mm 34PIN box header connector.
(4)SIO connector
Description: Connection to SIO unit.
Connector description: D_SUB 15PIN (Male) connector
Must use shielded twisted-pair type cable to reduce noise interference; ALNC can provide
standard wires for selection.
Separate these wiring min. 30 cm from themain circuit wiresand don't lay signal wires in the
same duct or bundle with them.

1.4.5 Analog output