I/O Mapping - Advantech LNC-5800D Hardware Maintenance Manual

Fieldbus controller
Table of Contents

Advertisement

3 I/O Mapping

Internal I/O
I point
Title
L_IN1
L_IN2
±IN
MPG Axis_X
MPG Axis_Y
MPG Axis_Z
MPG Axis_4
MPG Axis_5
MPG Axis_6
MPG Rate_x10
MPG Rate_x100
Servo_Alarm_SP1(AXIS 1)
Servo_Alarm_SP2(AXIS 2)
Initial key (the red key on the
back of mainframe)
Digital PCC3320/PCC3370=1
Lathe Machine OP panel (OP-2133)
I point
Name of key
CYCLE_START
FEED_HOLD
↓X
↑X
Y+
Y-
→Z
←Z
C+
C-
MPG_DRN
(handwheel simulation)
SBK(single block execution)
BDT(optional skip)
Serial No. Title
20000
Servo_Reset
20001
20002
20006
20007
Servo_ON_SP1(AXIS1)
20008
Servo_ON_SP2(AXIS2)
20009
20010
20011
20012
20013
20014
20015
20033
20063
Serial No.
Name of indicator
20100
CYCLE_START
20101
FEED_HOLD
↓X
20091
↑X
20067
20092
Y+
20090
Y-
→Z
20080
←Z
20078
20068
C+
20066
C-
MPG_DRN
20082
(handwheel simulation)
20070
SBK(single block execution)
20083
BDT(optional skip)
Advantech LNC Technology Co., Ltd.
O point
Serial No.
20003
20020
20021
O point
Serial
No.
20104
20105
20095
20071
20096
20094
20084
20082
20072
20070
20086
20074
20087
I
/O Mapping
33
Advantech-LNC

Advertisement

Table of Contents
loading