CellCOM Prime 7
* ALWAYS TEST THE UNIT ON SITE
BEFORE
Advanced Programming Setup
Note:
You need to send the SMS message created by the app to the intercom SIM number
4
and receive the 'OK' reply for correct programming. .
- Advanced GSM Intercom
INSTALLATION TO AVOID RE-STOCKING FEE *
See our YouTube
Channel for full app
walkthrough
or search
"AES Global"
on Youtube
See full T&C's on our website
INFORMATION
Norm:1234,5555,
6565,4321
Temp:
4545,7878,9876
Plan:1010,4343
(SMS Reply Examples)
SIGNAL STRENTH
Will reply with signal range
Intercom
1-31. Min signal level should
be 10 on 4G systems
*20#
STORED NUMBERS
Firmware:
O=Dial out number.
Cellcom Prime v2.1.2
I=Dial IN Caller ID number.
Network mode:4G
N = Another message to follow
Date:18/12/21
E = End of messages
Signal level: 18
APN:
RELAY STATUS
OPEN – Shows status of the input terminals called
DETECT - Can be used with a limit switch. Relay
status shown to check if any relay is latched.
Intercom
ACTIVITY LOG
*22#
Use this to see who used the
intercom and when. Which pin
codes were used, who used caller
Open
ID, who answered the call.
Relay1=OFF
TIP: Time and date is in
international military format.
Relay2=OFF
Intercom
STORED KEYPAD CODES
NORM=Permanent codes.
TEMP=Temporary codes.
1234#25#
PLAN=Time restricted codes.
STORED PROX ID CODES
NORM=Permanent codes.
TEMP=Temporary codes.
PLAN=Time restricted codes.
STILL HAVING TROUBLE?
Find all of our support options such as Web Chat,
Full Manuals, Customer Helpline and more on
our website:
WWW.AESGLOBALONLINE.COM
Intercom
*21#
O11:987654321
012:123456789
I1:987654321
I2:123456789
I3:5559991234
I4:99955598767
Intercom
*23#
0930-05/06/21-code-XX34-R1
1345-05/06/21-CID-543210
2034-04/06/21-user-55987
1632-04/06/21-code-XX89-R2
1244-04/06/21-code-XX98-R2
0840-04/06/21-CID-995555
2109-03/06/21-code-XX34
Last 6 digits of caller
2101-03/06/21-code-XX89-R2
ID user phone number
Last 2 digits of
keypad code used
Intercom
1234#26#
Norm:6897254836R1,
6548974581R2
Temp:
6989874154R1,
6989977415R1
Plan:6985332154R1