Quality Assurance Checklist - Cleveland (T) MKDL-100-T (-CC) Operator's Manual

Direct steam mixer kettles
Hide thumbs Also See for (T) MKDL-100-T (-CC):
Table of Contents

Advertisement

QUALITY ASSURANCE
Follow this list only after all other installation steps are completed.
Some steps require the use of equipment. Follow operating instructions.
The following will be performed before the unit is connected to utilities:
1. Visual
2. Visual
3. General
4. Level
The following will be performed with the unit connected to utilities:
5. Raise Bridge
6. Swing Bridge
7.
Tilt Kettle
8. Lower Bridge
9. Speed Control -
Main
10. Speed Control -
Secondary
11. Water Faucets
12. Product Discharge Add water to kettle. Check for leaks from valve. Open and close valve a few times
Valve
CHECKLIST
Examine unit for scratches, dents, or other defects.
Check flanged feet all have bolts holding them.
Check all accessible wiring, mechanical and plumbing connections by hand for
secure, tight and satisfactory assembly. Remove all paper.
Check unit has been leveled and squared correctly.
If bridge does not raise then check motor rotation. Bridge should not raise until
speed control is turned to minimum and then adjusted back up.
Bridge when fully raised should swing without hitting any object, i.e. control
housing, kettle lip. Check that hydraulic hoses are not being pinched by stops
on swivel assembly.
Kettle tilts smoothly both down and back up. If power tilt, check that micro
switches are adjusted properly (kettle is level in upright position and drains fully
when tilted) and are not being crushed by gear.
Raise bridge. Switch to mix. Turn speed control to zero to reset micro switch then
set speed control to number four. Check that unit does not begin to mix until
bridge has lowered part way into the kettle. Check that mixer bridge pin lowers
into pin hole correctly
Main agitator arm not rotating when set at minimum but will start to move slowly on
one. Speed control makes positive contact with micro switch.
Set main speed control to five. Adjust secondary control from
minimum to maximum. Look for considerable speed variance.
Turn on hot water faucet. Turn off and check for leaks in piping and drips from
faucet spout. Repeat above with cold water faucet.