INSTALLATION
2.4

ELECTRICAL CONNECTIONS

2.4.1

System Wiring

The connection and wiring procedure for DP1200 is described as follows:
1)
Open the DP1200 as described in paragraph 2.2.
2)
Verify that the DP1200 power switch is off (see Figure 6).
3)
Unscrew the compression connectors and pass all the system cables through
them in the device housing.
4)
To connect the power and input/output signals:
Prepare the individual wires of the system cables by stripping the insulation back
approximately 1 cm.
Using a device such as a screwdriver, push down on the lever directly next to
the clamp (see Figure 5).
Insert the wire into the clamp and release the lever.
The wire will now be held in the spring clamp.
The wiring used can be solid or stranded but must meet the following specifications.
All the positions:
Figure 5 - System cable connections
24 - 16 AWG
0.2 - 1.5 mm²
2