Typical Layouts; Point-To-Point - Datalogic DP1200 Installation Manual

Table of Contents

Advertisement

INSTALLATION
2.5

TYPICAL LAYOUTS

The following typical layouts refer to system hardware configurations. Dotted lines in
the figures refer to optional hardware configurations within the particular layout.
These layouts also require the correct setup of the software configuration
parameters. Complete software configuration procedures can be found in the Guide
To Rapid Configuration in the WinHost Help On Line.
2.5.1

Point-to-Point

In this layout the data is transmitted to the Host on the main serial interface. Host
Mode programming can be accomplished either through the main interface or the
auxiliary interface.
In Local Echo communication mode, data is transmitted on the RS232 auxiliary
interface independently from the main interface selection.
When On-Line Operating mode is used, the system is activated by an External
Trigger (photoelectric sensor) when the object enters its reading zone.
LSXXXX
reader
Terminal
3
1
2
3
Figure 24 - Point-to-point layout
2
Main serial interface
Auxiliary serial interface (Local Echo)
External Trigger (for On-Line mode)
DP1200
Host
1
2
25