V. Troubleshooting Guide
V. TROUBLESHOOTING GUIDE
4.01
TROUBLESHOOTING GUIDE & ADDITIONAL HELP
PROBLEM:
Reversed Polarity LED is on and the unit is not operational
SOLUTION: Polarity is Reversed on vehicle's battery connection.
Check connection; Red to positive and Black to vehicle ground as
far away from the battery as leads will allow.
PROBLEM:
The unit will not power up.
SOLUTION: Check for proper connection on power leads. Verify proper voltage at
battery (see Battery Voltage Chart on page 14).
NOTE: If voltage was incorrect (above 18.0 VDC) disconnect leads
PROBLEM:
Pump is running but unit will not build pressure.
SOLUTION: Check for proper connection on power leads. Verify proper voltage at
battery (see Battery Voltage Chart on page 14).
PROBLEM:
Unit performs poorly.
SOLUTION: • Check hoses for damage.
• Check power leads for cuts or frays.
PROBLEM:
Does not pull fluid from transmission.
SOLUTION: • Verify voltage output from battery (12.6VDC or above).
• Verify that power leads are securely connected to battery.
• Verify that black external hose is properly connected to
wand assembly.
• Verify proper seal on dipstick tube and wand connection.
24
& ADDITIONAL HELP
and reconnect to proper power source. This will reset unit.
Manual Printed in the U.S.A. for AEC GROUP INC.
Advantage Engineering® TRANS PRO X-Series™
Operations Manual