Section 3.05: Manual/Top Off Mode - Advantage Engineering TRANS PRO X Series Operation Manual

Table of Contents

Advertisement

IV. Operating Procedures
Advantage Engineering® TRANS PRO X-Series™
3.05 MANUAL/TOP OFF MODE – OPERATING PRODECURE
(Used ATF and new ATF are transferred through the transmission's dipstick tube to the
transmission system with this mode)
This mode is used when the transmission pan needs to be removed (to change gaskets or
replace filter). It is also used to top off the ATF fluid level when necessary.
NOTE: Confirm vehicle and transmission are at operating temperature before initiating service!
Power up. Connect power cord to 12.0 VDC battery. REFER TO BATTERY VOLTAGE
CHART ON PAGE 14. Connect the positive lead of the equipment to the positive lead of the
battery first. Connect the negative lead of the equipment to vehicle ground as far away from
the battery as the leads will allow to prevent sparking and igniting of battery gases. Note:
The REVERSED POLARITY LED will light if connected improperly.
The TRANS PRO will self test. The buzzer will sound, all LEDs and display segments will
light briefly, and software version will be displayed.
The SELECT key and DIPSTICK ONLY, MANUAL/TOP-OFF, DRAIN WASTE TANK, and TOTAL
COUNT LEDs will light and flash (additional COOLER LINE LED visible on TRANS PRO+ model).
Remove dipstick from transmission. Note dipstick length. Insert flexible nylon dipstick tube
to length of dipstick being mindful that it may be necessary to insert slightly farther until the
bottom of the pan is reached.
Depress the SELECT key until the LED for the proper function is lit. (Note: The lit LED will
move from option to option i.e. MANUAL/TOP-OFF, DRAIN WASTE TANK, and TOTAL
COUNT, etc. each time it is depressed). When the LED for the MANUAL/TOP-OFF mode is lit
and flashing, pause for one second.
The ENTER key LED will then light and flash. Depress ENTER to confirm.
The CHECK TRANS LEVEL LED will light. TO TRANS, FROM TRANS, FINISH, and SELECT
LEDs will flash. The display will also flash DRN PAN. Depress the SELECT key to toggle
between these four selections. Pause when the LED for the appropriate selection or the DRN
PAN display is lit. Depress ENTER to confirm.
If TO TRANS or FROM TRANS is selected, follow the procedure below.
Depress the ADD (ARROW UP) key to enter the volume of new ATF to be added (if TO
TRANS is selected). This key is also used to enter the volume of ATF to be extracted (if
FROM TRANS is selected). The volume for adding or extracting is measured in increments of
.1 (1/10) quart.
20
Operations Manual
Manual Printed in the U.S.A. for AEC GROUP INC.

Advertisement

Table of Contents
loading

Related Products for Advantage Engineering TRANS PRO X Series

This manual is also suitable for:

Trans pro