IV. Operating Procedures
3.07 TOTAL COUNT – OPERATING PRODECURE
(Used ATF is transferred from the internal waste tank of TRANS PRO through the drain
adapter to an external waste ATF reservoir with this mode)
Power up. Connect power cord to 12.0 VDC battery. Connect the positive lead of the equip-
ment to the positive lead of the battery first. Connect the negative lead of the equipment to
vehicle ground as far away from the battery as the leads will allow to prevent sparking and
igniting of battery gases. Note: The REVERSED POLARITY LED will light if connected
improperly.
The TRANS PRO will self test. The buzzer will sound, all LEDs and display segments will
light briefly, and software version will be displayed.
The SELECT key and DIPSTICK ONLY, MANUAL/TOP-OFF, DRAIN WASTE TANK, AND
TOTAL COUNT LEDs will light and flash.
Depress the SELECT key until the LED for the proper function is lit. (Note: The lit LED will
move from option to option i.e. MANUAL/TOP-OFF, DRAIN WASTE TANK, and TOTAL
COUNT, etc. each time it is depressed). When the LED for the DRAIN WASTE TANK TOTAL
COUNTmode is lit and flashing, pause for one second.
The ENTER key LED will then light and flash. Depress ENTER to confirm.
The display will show total services performed. The FINISH LED will also flash. Depress
ENTER to return to mode selection after you note the total services.