Section 3.04: Cooler Only Mode (Trans Pro+ Feature) - Advantage Engineering TRANS PRO X Series Operation Manual

Table of Contents

Advertisement

IV. Operating Procedures
Advantage Engineering® TRANS PRO X-Series™
3.04
COOLER ONLY MODE – OPERATING PRODECURE
(Used ATF and new ATF are transferred through the cooler lines to the transmission
system with this mode
NOTE: Confirm vehicle and transmission are at operating temperature before initiating service!
Power up. Connect power cord to 12.0 VDC battery. REFER TO BATTERY VOLTAGE
CHART ON PAGE 14. Connect the positive lead of the equipment to the positive lead of the
battery first. Connect the negative lead of the equipment to vehicle ground as far away from
the battery as the leads will allow to prevent sparking and igniting of battery gases. Note:
The REVERSED POLARITY LED will light if connected improperly.
The TRANS PRO+ will self test. The buzzer will sound, all LEDs and display segments will
light briefly, and software version will be displayed.
Identify and select an appropriate Automatic Transmission cooler line. Disconnect and
attached appropriate adapters to the previously selected cooler line, either at transmission or
at radiator, whichever is most convenient.
Attach cooler line adapters to TRANS PRO+ selector valve assembly. Disconnect TRANS
PRO+ red and black hoses from dipstick nozzle assembly and attach lines to fittings on
selector valve assembly.
The SELECT key and DIPSTICK ONLY, COOLER ONLY, DRAIN WASTE TANK, AND TOTAL
COUNT LEDs will light and flash.
Depress the SELECT key until only the LED for the COOLER ONLY function is illuminated.
Pause for one second.
The ENTER key LED will then light and flash. Depress ENTER to confirm.
The left display indicating the quantity of new ATF for the service will show "12" and the
ADD (ARROW UP) and SUBTRACT (ARROW DOWN) LEDs will flash.
Select the quantity of ATF to be used for the service (default is 12 quarts; minimum is 6
quarts, maximum is 32 quarts). Add or subtract in one (1) quart increments by depressing
the ADD (ARROW UP) or SUBTRACT (ARROW DOWN) buttons below the display. Depress
ENTER key to confirm the quantity displayed.
The alarm will sound and the START ENGINE and ENTER LEDs will flash. Press ENTER to
start the ATF service, then start the engine.
18
Operations Manual
Manual Printed in the U.S.A. for Snap-on Tools ®

Advertisement

Table of Contents
loading

Related Products for Advantage Engineering TRANS PRO X Series

This manual is also suitable for:

Trans pro

Table of Contents