2.9. Specification table

DC inputs
Recommended power range of PV array
Maximum input voltage
(2)
MPP Voltage range
Operating voltage range
Minimum voltage for Pnom
Maximum short circuit current
Maximum inverter backfeed current to the PV array.
MPPT number
Number of strings (PRO version / STD version)
Maximum input current
Maximum input current per string
AC output
Rated power
Maximum continuous power
Max. temperature for rated power
Maximum current
Inrush current
Maximum output fault current
Maximum output overcurrent protection
Rated voltage
Configurable rated voltages
Nominal frequency
Cosine of Phi
Adjustable cosine of phi
THD
(3)
Type of grid
Performance
Maximum efficiency
Euroefficiency
General data
Cooling system
Air flow
Weight (PRO version / STD version)
Dimensions (height x width x depth)
Stand-by consumption
(4)
Night consumption
Operating temperature
Relative humidity (without condensation)
Maximum altitude of the installation
Protection class
Markings
RCD
EMC and safety regulations
Grid connection regulations
(1)
Depending on the type of installation and the geographic location.
at low temperatures.
For rated PAC and voltage according to
(3)
70
(1)
(2)
Never exceed this value.
IEC 61000-3-4.
56 ~ 80.2 / 91,1 ~ 130.5 / 96.2 ~ 137.8 / 101.2 ~ 145 / 106.3 ~ 152.3 /
111.3 ~ 159.5 kWp
1100 V (<1000 V to start production)
513 / 541 / 570 / 599 / 627 ~ 850 V
513 / 541 / 570 / 599 / 627 ~ 1000 V
513 / 541 / 570 / 599 / 627 V
185 Adc
90 / 95 / 100 / 105 / 110 kW
90 / 95 / 100 / 105 / 110 kW
<145 Arms 60ms
<220 Arms 160 ms
160 Arms
360 / 380 / 400 / 420 / 440 V
50 / 60 Hz
Yes. Smax = 100 kVA; Qmax = 60 kVAR
Forced ventilation
570 m
78/75 kg
905 x 720 x 315 mm
-25 ºC ~ 60 ºC
0 ~ 100%
3000 m (after 1000 m the maximum temperature decreases)
1000 mA
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-4, IEC 61000-3-11,
IEC62109-1, IEC62109-2, IEC62103, IEC 61000-3-12, EN50178, FCC
Part 15, IEC60068-2-1, IEC60068-2-2, IEC60068-2-14, IEC60068-2-30,
IEC60068-2-68, IEC 60529
Arrêté du 23 avril 2008, VDE0126-1-1, EN 50549, CEI 0-16, VDE-AR-N
4105:2011-08, P.O.12.3, AS4777.2,BDEW, IEC 62116, IEC 61727, UNE
206007-1, ABNT NBR 16149, ABNT NBR 16150, Brazilian Grid code,
South African Grid code, Chilean Grid Code, DEWA 2.0, Chilean Grid Code,
Jordan Grid Code, Thailand MEA & PEA requirements
Consider the voltage increase of the panels 'Voc'
Consumption from the PV array.
(4)
ABS2011IQM01_G - Installation and Operation Manual
Unit description
100TL
240Adc
1.7 kA
1
24 / 1
15 Adc
50 ºC
145 A
400 V
1
<3%
TT, TN
98.8%
98.5%
/h
3
20 W
1 W
IP65
CE