Beckhoff EP3752-0000 Documentation page 45

2 x 3-axis accelerometers
Hide thumbs Also See for EP3752-0000:
Table of Contents

Advertisement

Index 1C33 SM input parameter
Index (hex) Name
1C33:0
SM input parameter Synchronization parameters for the inputs
1C33:01
Sync mode
1C33:02
Cycle time
1C33:03
Shift time
1C33:04
Sync modes sup-
ported
1C33:05
Minimum cycle time Minimum cycle time supported (in ns)
1C33:06
Calc and copy time
1C33:07
Minimum delay time
1C33:08
Command
1C33:09
Maximum Delay
time
1C33:0B
SM event missed
counter
1C33:0C
Cycle exceeded
counter
1C33:0D
Shift too short
counter
1C33:20
Sync error
EP3752-0000
Meaning
Current synchronization mode:
• 0: Free Run
• 1: Synchron with SM 3 Event (no outputs available)
• 2: DC - Synchron with SYNC0 Event
• 3: DC - Synchron with SYNC1 Event
• 34: Synchron with SM 2 Event (outputs available)
Cycle time (in ns):
• Free Run: Cycle time of the local timer
• Synchron with SM 2 Event: Master cycle time
• DC mode: SYNC0/SYNC1 Cycle Time
Time between SYNC0 event and reading of the inputs
(in ns, only DC mode)
Supported synchronization modes:
• Bit 0: free run is supported
• Bit 1: Synchron with SM 2 Event is supported
(outputs available)
• Bit 1: Synchron with SM 3 Event is supported (no
outputs available)
• Bit 2-3 = 01: DC mode is supported
• Bit 4-5 = 01: Input Shift through local event
(outputs available)
• Bit 4-5 = 10: Input Shift with SYNC1 event (no
outputs available)
• Bit 14 = 1: dynamic times (measurement through
writing of 0x1C32:08 or 0x1C33:08)
Time between reading of the inputs and availability of
the inputs for the master (in ns, only DC mode)
With this entry the real required process data provision
time can be measured.
0: Measurement of the local cycle time is stopped
1: Measurement of the local cycle time is started
The entries 0x1C33:03, 0x1C33:06, 0x1C33:09 are up-
dated with the maximum measured values.
For a subsequent measurement the measured values
are reset
Time between SYNC1 event and reading of the inputs
(in ns, only DC mode)
Number of missed SM events in OPERATIONAL (DC
mode only)
Number of occasions the cycle time was exceeded in
OPERATIONAL (cycle was not completed in time or the
next cycle began too early)
Number of occasions that the interval between SYNC0
and SYNC1 event was too short (DC mode only)
The synchronization was not correct in the last cycle
(outputs were output too late; DC mode only)
Version: 1.4
CoE parameters
Data type
Flags Default
UINT8
RO
0x20 (32
UINT16
RW
0x0022 (34
UINT32
RW
0x000F4240
(1000000
UINT32
RO
0x00000000 (0
UINT16
RO
0x0003 (3
UINT32
RO
0x0003D040
(20000
UINT32
RO
0x00000000 (0
UINT32
RO
0x00000000 (0
UINT16
RW
0x0000 (0
UINT32
RO
0x00000000 (0
UINT16
RO
0x0000 (0
UINT16
RO
0x0000 (0
UINT16
RO
0x0000 (0
BOOLEAN
RO
0x00 (0
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec